Rated 4.9 from 170+ Google reviews Serving the North West for over ten years 0161 427 0772
Elastochem Insulthane 50 · Open cell

Open cell spray foam for new build and timber frame

Insulthane 50 is a water-blown, open cell spray foam that forms a seamless insulating layer between rafters, studs and joists. We install it on new-build, timber-frame, commercial and specification-led projects as an Elastochem Approved Installer.

Open cell spray foam being applied between the rafters of a timber-frame roof
  • Elastochem Approved InstallerView our listing
  • Kiwa BDA Agrément®five certificates for Insulthane 50
  • New & existingresidential and non-residential
  • Survey & designfor every project
Where we use it

Built for specification-led projects

Open cell spray foam expands to fill the space between structural members, sealing around awkward details and reducing thermal bridging and air leakage at the same time. It suits:

  • New-build homes and developments – pitched and flat roofs, walls and suspended floors
  • Timber-frame construction – between the studs of sheathed timber-frame walls with a masonry outer leaf
  • Suitable wall and roof applications – including warm pitched roofs and solid masonry walls (on a studwork frame)
  • Commercial and non-residential buildings
  • Projects requiring professional insulation specification – working with architects, builders and developers
Open cell spray foam in a timber-frame roof with rooflights Spray foam insulated roof space ready for boarding
Certification

Kiwa BDA Agrément® certificates for Insulthane 50

Insulthane 50 holds five BDA Agrément® certificates issued by Kiwa Ltd. Each covers new and existing, residential and non-residential buildings, within the scope below.

CertificateApplicationScope
BAR-24-322-P-A-UKPitched roofsBetween timber rafters onto a low resistance (LR) underlay or sarking boards, or a high resistance (HR) underlay in retrofit applications only. Alternatively at ceiling level where the attic is non-habitable.
BAR-24-364-P-A-UKVentilated pitched roofsBetween timber rafters onto a breathable vent card, maintaining a 50 mm ventilated void below an HR or LR underlay or sarking boards.
BAR-24-323-P-A-UKFlat roofsInternally, to the underside of flat roofs with a timber or concrete deck.
BAW-24-325-P-A-UKWallsInternally on solid masonry walls, or between the studs of sheathed timber- or steel-framed walls with an outer masonry leaf.
BAF-24-324-P-A-UKSuspended ground floorsBetween the joists of suspended timber ground floors.

Certificate validity is as published at kiwa.co.uk/bda. Use in walls is subject to the building height limits set out in the walls certificate. Full certificates are available to download below.

How we work

Survey, design, install, document

  1. Pre-installation survey

    We check the structure, membranes or sheathing, timber moisture content (below 19%), ventilation, services and any areas not to be treated.

  2. Project-specific design

    Developed with Elastochem, including U-value calculations and a condensation risk analysis to BS 5250.

  3. Installation

    Applied by our trained operatives as an Elastochem Approved Installer, in layers to the specified thickness – with flues, cables and recessed lighting dealt with correctly.

  4. Handover

    Appropriate technical documentation for the project, provided on completion.

Key technical data

TypeIn-situ formed, water-blown, semi-rigid open cell PUR foam (BS EN 14315)
Thermal conductivity (λD)0.038 W/mK, 50–400 mm
Installed density7–12 kg/m³
Water vapour diffusion factor (µ)3.68
Maximum thickness400 mm
Reaction to fireEuroclass F – must be covered by a suitable lining, such as plasterboard, as set out in the certificates
DurabilityService life equivalent to that of the building

Structural warranties: Kiwa's opinion is that the product can satisfy the requirements of a structural warranty provider when installed in accordance with the certificates. Acceptance is confirmed by the warranty provider on a case-by-case basis.

Free quote

Send us your project

Drawings, specifications or U-value targets are welcome. We'll review them and come back to you with our recommendations and a quote.

We only use your details to respond to your enquiry. See our privacy policy.